Skip to content

Zigbee setup ​

Zigbee is the low-power option. On batteries it is the only sensible choice: the radio is active for a fraction of the time Wi-Fi needs, and the mesh relays messages through routers so the device does not need a strong direct link.

ZiggyMeter joins as a Zigbee End Device. It is not a router and not a coordinator.

What you need ​

  • A Zigbee coordinator — a hub, or a USB adapter running software such as Zigbee2MQTT, ZHA in Home Assistant, or a commercial gateway
  • The coordinator must accept third-party devices, not only its vendor's own products
  • Support for Zigbee Cluster Library v8 clusters, which is what ZiggyMeter exposes

Enable Zigbee on the device ​

Zigbee is disabled by default. Turn it on in the web interface:

  1. Open Zigbee.
  2. Set Configuration to ENABLED.
  3. Select UPDATE.

WARNING

Changing the Zigbee enable state restarts the device.

Join a network ​

  1. Enable permit-join on your coordinator. In Zigbee2MQTT this is Permit join at the bottom of the menu; in ZHA it is Add device; hubs usually have an "add device" button.

  2. Put ZiggyMeter into joining mode, either way:

    • Button — click 3 times in quick succession. If the device is asleep, use 4 clicks: the first click only wakes it.
    • Web interface — Zigbee → ZIGBEE RESET.

    The blue LED blinks slowly while the device looks for a network:

  3. Wait for the coordinator to find it. Once joined, the blue LED goes solid:

    and the Zigbee page fills in the channel, short address, PAN ID and extended PAN ID.

INFO

A Zigbee reset removes the device from its current network before looking for a new one. Use it whenever you move the device to a different coordinator.

Verify ​

On the Zigbee page, the Status section should show:

FieldWhat it means
ChannelRadio channel of the network, 11–26
Short address16-bit address the coordinator assigned
PAN ID16-bit network identifier
Extended PAN ID64-bit unique network identifier

Empty fields mean the device has not joined. Check that permit-join is still open and that the device is in range of the coordinator or a mains-powered router.

What the device exposes ​

Two endpoints, all standard ZCL clusters — no manufacturer-specific extensions:

EndpointPurpose
1Device identification, battery, temperature. The On/Off switch enables or disables Wi-Fi.
2Meter data. The On/Off switch triggers a meter reading.

The full cluster and attribute list is in Integrations → Zigbee.

Wi-Fi while running on Zigbee ​

You can still bring Wi-Fi up temporarily — to change a setting or use the API — by holding the button for 3 seconds. It is not permanent; the device returns to Zigbee-only operation afterwards.